Known Issues

NISAR products have been released with three different maturity levels, and each release has a unique suite of known issues. This page focuses on known issues with the VALIDATED product collections.

To learn about the known issues for PROVISIONAL or BETA products, click the buttons below.

PROVISIONAL Known Issues BETA Known Issues

Validated Product Known Issues

The VALIDATED products released in November 2026 are fully calibrated and validated.

While these products meet calibration and validation requirements for the mission, there are some known issues that users should be aware of. Some of these issues are inherent to the mission data, while others have the potential to be addressed in the future using new processing approaches.

Known issues with the NISAR data are tracked in Table 1, and additional issues that surface over time will be added as information becomes available. Entries will be updated as issues are resolved or determined to be permanent.

If you encounter issues with NISAR products that are not addressed here, please post them to NASA’s Earthdata Forum.

Known Issues Table

Table 1 summarizes the known issues for NISAR VALIDATED products. Each issue is linked to a more detailed description.

Table 1:NISAR Known Issues Table

Issue SummaryDate AddedStatus
Incomplete L0B Products05 Nov 2026Resolved with CRID P05036
Permanent NISAR instrument data gap between 2026-07-27 and 2026-08-1010 Aug 2026Permanent issue

Current Known Issues

These issues are currently impacting VALIDATED products. Some issues are unresolvable, but others may be mitigated in future updates to the NISAR processing software.

Permanent data gap

No data was collected by the NISAR platform between 2026-07-27T22:03:25Z and 2026-08-10T00:55:27Z. There are not currently any VALIDATED products available for this time range, but once the reprocessing campaign is complete, this data gap will be present in the VALIDATED collections, as well.

Resolved Known Issues

Incomplete L0B Products

Resolved with CRID P05036

One of the most critical issues with the PROVISIONAL products was a timestamp issue that resulted in incomplete L0B products. This manifested in downstream product types as a range of artifacts, including defocused RSLC images, missing data, and decorrelation in InSAR products. The majority of issues with PROVISIONAL products reported to the Earthdata Forum were caused by this issue, but it was resolved before VALIDATED data products were processed.